Liquid cooling rack manifold in a data center cold aisle
Industries · Liquid Cooling Loops

Liquid-cooled industries, one dry-break interface.

From GPU racks moving roughly 100 kW through cold plates to battery containers holding a 3°C cell spread, every loop we build for ends the same way: a coupling that opens dry, closes dry and ships with its own test record. The share of AI servers delivered liquid-cooled has run from 15% in 2024 to a projected 76% in 2026 — the hardware underneath that curve has to disconnect cleanly, every time.

Where The Loops Run

Six programs, one interface discipline.

DryLink UQD and UQDB sets plus rack manifolds are configured per program — the mating envelope stays OCP UQD Rev 1.0, while port maps, seal compounds and documentation follow the industry in question.

AI · GPU Racks

AI Data Centers

Liquid-cooled AI servers climb from 15% of shipments in 2024 to a projected 76% in 2026, and an NVL72-class rack pushes about 100 kW through its cold plates. UQDB blind-mate sets and manifold drops keep every tray swappable without draining a liter of glycol.

AI data centers
HPC · Green500

HPC & Supercomputing

The systems at the top of the Green500 efficiency list are all direct liquid-cooled, running at 60–70 GFLOPS per watt. Warm-water loops, serviceable node drops and documented cleanliness form the delivery checklist our couplings are gauged against.

HPC & supercomputing
OEM · CDU Programs

Server & CDU OEMs

In-rack CDUs span 15–125 kW and server modules already take about 56% of rack pressure drop, so ports and manifolds have to be low-resistance by design. We build to your drawing, your port map and your quality gate — FAI and PPAP files included.

Server & CDU OEMs
Edge · Colocation

Edge & Colocation

AI clusters push past 150 kW per rack into buildings that were never plumbed for coolant, while rack-class rear-door liquid cooling already carries 75 kW. Single-hand, dripless disconnects are what turn a tray swap into a five-minute job instead of a service incident.

Edge & colocation
ESS · Battery Packs

Energy Storage

Liquid cooling holds cell-to-cell spread at 3°C or better inside the 15–35°C window lithium tolerates, and stationary BESS liquid cooling is forecast to compound at 23.1% a year. Pack- and cluster-level quick disconnects make module service dry and toolless.

Energy storage
Labs · Sample Kits

Integrators & Test Labs

Test benches and integration lines run on small, fast batches: MOQ from 50 pieces, evaluation kits assembled to your interface list, samples shipping in 15 days with the leak and material paperwork a qualification file actually asks for.

Integrators & labs
Market Numbers

The loop is growing faster than the rack count.

Every forecast below lands on the same conclusion: more coolant, moving through more connections, per building — which puts the coupling on the critical path of the whole build.

76%AI servers liquid-cooled in 2026 — from 15% in 2024
$27.65Bdata center liquid cooling market by 2033 · 31.5% CAGR
$15.99Bliquid cooling manifold market on the same forecast
27kWaverage rack density in 2026, up 69% year over year

Tell us where the loop runs. We will match the interface.

AI racks, supercomputers, CDU programs or battery packs — send the loop conditions and get a bore-to-bore quote within 48 hours. MOQ from 50 pieces, FOB · CIF · DDP.